I recently installed a thermostat "Rite Temp digital and my house is cold.?

I do not know if it is not installed correctly. I think not. But my house is freezing. Do not exceed 62, and the heat worked all day for two days (I'm in Baltimore … time in the 50s on Saturday). I even went and had planned and carried out of the factory installed program. I have a heat pump … could be why the heat does not build the house? The air leaving the mouth is not too hot – is a kind of cooler. Someone told me it could be that the house needs only 3 days to get warm. The heat pump is only four years … I think something might be wrong with him, but I think not. Someone told me the pumps usually only Heat pump air cooler. Oh, yes, this is only my second winter in the house, so I'm still learning its nuances. Anyway, I seem to recall that this problem before installing digital thermostat Rite Temp. Anyone who can help?

It appears you have not connected secondary heat strips when he changed the thermostat. Heat pumps installed at the cooler climates can not heat their home satisfactorily only by heat transfer between the outside air, they need a secondary source of heat. This is usually electric heat thermostat strips.The stability of the connection in most systems is W2. I suggest you do a professional to check the system and test the new thermostat is compatible with your system. Connect the cable to the wrong thermostat can cause damage to the control processor and / or circuit.

Share and Enjoy:
  • Print
  • Digg
  • Sphinn
  • del.icio.us
  • Facebook
  • Mixx
  • Google Bookmarks
  • Add to favorites
  • Twitter
  • Technorati
  • StumbleUpon
  • Live
  • NewsVine
  • RSS
Categories: plumbing Tags: , , , ,
  1. No comments yet.
  1. No trackbacks yet.
You must be logged in to post a comment.